Assured Home Inspections Inc.4109 Waterford Dr. | |||
|
Customer | |||
|
Home | |||
|
Real Estate Agent | |||
| |||
| |||
| |||
![]() |
![]() |
| Date: 2/7/2007 | Time: 9:07 PM | Report ID: |
| Property: 10474 Bethpage Dr. Fort Mill, SC 29715 |
Customer: Mr. Tommy Merritt Mrs. Peggy Meritt |
Real Estate Professional: Andy Man Pulte |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: New Construction |
Client Is
Present: Yes |
Radon Test: No |
| Water Test: No |
Weather: Clear |
Temperature: Below 60 |
| Rain in last 3
days: No |
|
Styles &
Materials Roof Covering: Architectural Viewed roof covering from: Ground Binoculars Sky Light(s): None Chimney (exterior): Metal Flue Pipe | ||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Styles &
Materials Siding Style: Lap Rock and Mortar Siding Material: Vinyl Stone Exterior Entry Doors: Fiberglass Appurtenance: Covered porch Driveway: Concrete | ||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Styles &
Materials Garage Door Type: One automatic Garage Door Material: Metal Auto-opener Manufacturer: LIFT-MASTER | ||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
Styles &
Materials Ceiling Materials: Sheetrock Wall Material: Sheetrock Floor Covering(s): Carpet Hardwood T&G Tile Interior Doors: Hollow core Raised panel Window Types: Thermal/Insulated Single-hung Window Manufacturer: UNKNOWN Cabinetry: Wood Countertop: Granite | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Styles &
Materials Foundation: Poured concrete Method used to observe Crawlspace: No crawlspace Floor Structure: Engineered floor joists Wall Structure: Wood Columns or Piers: Wood piers Ceiling Structure: Not visible Roof Structure: Engineered wood trusses Roof-Type: Gable Method used to observe attic: Walked Attic info: Pull Down stairs | ||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
|
Styles &
Materials Water Source: Public Water Filters: None (We do not inspect filtration systems) Plumbing Water Supply (into home): Pex Plumbing Water Distribution (inside home): PEX Washer Drain Size: 2" Diameter Plumbing Waste: PVC Water Heater Power Source: Gas (quick recovery) Water Heater Capacity: 50 Gallon (2-3 people) Manufacturer: STATE | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Styles &
Materials Electrical Service Conductors: Below ground Panel capacity: 200 AMP Panel Type: Circuit breakers Electric Panel Manufacturer: SQUARE D Branch wire 15 and 20 AMP: Copper Wiring Methods: Romex | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
|
Styles &
Materials Heat Type: Forced Air Energy Source: Gas Number of Heat Systems (excluding wood): Two Heat System Brand: LENNOX Ductwork: Insulated Filter Type: Disposable Types of Fireplaces: Vented gas logs Operable Fireplaces: One Number of Woodstoves: None Cooling Equipment Type: Air conditioner unit Cooling Equipment Energy Source: Electricity Central Air Manufacturer: LENNOX Number of AC Only Units: Two | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Styles &
Materials Attic Insulation: Blown Ventilation: Ridge vents Soffit Vents Exhaust Fans: Fan only Dryer Power Source: 220 Electric Dryer Vent: Metal Floor System Insulation: Faced Batts Fiberglass R-19 | ||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
Styles &
Materials Dishwasher Brand: GENERAL ELECTRIC Disposer Brand: IN SINK ERATOR Exhaust/Range hood: RE-CIRCULATE Range/Oven: GENERAL ELECTRIC Built in Microwave: GENERAL ELECTRIC Trash Compactors: NONE Refrigerator: GENERAL ELECTRIC | ||||||||||||||||||||||||||||||||||||||||||||||||
![]() Assured Home Inspections Inc. 4109 Waterford Dr. |
|
Customer |
|
Property Address |
| 1.0 | ROOF COVERINGS | ||||||||||
| Inspected, Repair or Replace | |||||||||||
|
The roof covering shows dip or
hump at the front of home. This damage should be repaired or
replaced. A qualified person should repair or replace as
needed.
| |||||||||||
| 1.3 | ROOF DRAINAGE SYSTEMS | ||||||||||
| Inspected, Repair or Replace | |||||||||||
|
(1) The downspout needs an extension and a
buried drain line to carry water away from the home at the front, rear and
sides of home.
| |||||||||||
|
(2) The downspout is loose and needs securing
to the wall at the patio.
| |||||||||||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |||
| Inspected, Repair or Replace | ||||
|
(1) The rock siding at the front of home
is not supported at bottom. Deterioration can eventually occur if not
corrected. A qualified person should repair or replace as
needed.
| ||||
|
(2) The rock siding at the front of home
missing. Deterioration can eventually occur if not corrected.
A qualified person should repair or replace as needed.
| ||||
|
(3) The hole in basement wall needs closing
off with sealant or liquid foam at the left side (facing front) where
compressor lines enter the home.
| ||||
|
(4) The vinyl siding at the exterior does not
cover lower edge of wall sheathing.. Deterioration can eventually occur if
not corrected. A qualified person should repair or replace as
needed.
| ||||
|
(6) There is exposed treated wood at rear
corners, is this wood classified for contact with dirt and concrete?
| ||||
|
(7) The vinyl siding at the exterior rear of
home is not properly installed. Repairs are needed using a
qualified person.. Deterioration can eventually occur if not corrected.
A qualified person should repair or replace as needed.
| ||||
|
(8) The vinyl siding at the exterior nailed to
tight, unable to move siding at several areas.. Deterioration can
eventually occur if not corrected. A qualified person
should repair or replace as needed.
| ||||
| 2.1 | DOORS (Exterior) | |||
| Inspected, Repair or Replace | ||||
|
(1) The main entry door rear of home at
basement needs caulking at threshold, brick mold and lower board. A
repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||
|
(2) The main entry door front of home needs
caulking at threshold, brick mold and bottom board. A repair or
replacement is needed. A qualified person should repair or
replace as needed.
| ||||
| 2.2 | WINDOWS | |||
| Inspected, Repair or Replace | ||||
|
The window frame is not caulked at rear
of home. Deterioration may occur if not corrected. A qualified
person should repair or replace as needed.
| ||||
| 2.5 | EAVES, SOFFITS AND FASCIAS | |||
| Inspected, Repair or Replace | ||||
|
The fascia board at eave on the front of home
not installed properly. Deterioration may occur if not corrected.
A qualified person should repair or replace as needed.
| ||||
| 3.3 | GARAGE DOOR (S) | ||
| Inspected, Repair or Replace | |||
|
Garage door jams need caulking at bottom where
they meet the concrete.
| |||
| 4.1 | WALLS | |||||
| Inspected, Repair or Replace | ||||||
|
(1) The sheetrock on the wall is damaged at
the closet in foyer. Repairs are needed. A qualified person
should repair or replace as needed.
| ||||||
|
(2) The sheetrock on the wall is bowed or
bulges and cracked at basement.. Possibly from poor nailing or
moisture absorption. While this damage is cosmetic, it needs to be
repaired. A qualified person should repair or replace as
needed.
| ||||||
| 4.2 | FLOORS | |||||
| Inspected, Repair or Replace | ||||||
|
(1) The Tile is missing grout at the mud room.
Repairs are needed. A qualified person should repair or replace
as needed.
| ||||||
|
(2) The tile is weak and not supported from
underneath at the Washer/Dryer room. Repairs are needed. A qualified
person should repair or replace as needed.
| ||||||
|
(3) Basement floor has void between exterior
walls. Area needs filled with concrete calk. Repairs are needed using a
qualified person.
| ||||||
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |||||
| Inspected, Repair or Replace | ||||||
|
(1) Drawer track and cabinet is damaged
under stove. Recommend repair or replace as necessary.
| ||||||
|
(2) Drawer track in master bath is damaged. I
recommend repair or replace as necessary.
| ||||||
|
(3) Cabinet baseboard is damaged and is
unfinished at island (left of dishwasher) , (left of stove) and hall
bath in basement.. This is a cosmetic issue for your information.
Recommend repair or replace as necessary.
| ||||||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | |||||
| Inspected, Repair or Replace | ||||||
|
(1) The pantry door needs adjustment at the
Kitchen. A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(2) The entry door French doors rubs floor
when opened. Door needs to be trimmed at bottom by a skilled craftsman and
does not shut properly at the office. A repair or replacement is needed.
A qualified person should repair or replace as needed.
| ||||||
|
(3) The entry door has improperly installed
hardware that was not installed correctly at the half bath. A repair
or replacement is needed. A qualified person should repair or
replace as needed.
| ||||||
|
(4) The closet door is damaged at the rear
bedroom. A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(5) The entry door does not shut properly at
the rear bedroom. A repair or replacement is needed. A qualified
person should repair or replace as needed.
| ||||||
|
(6) The entry door rubs floor when opened.
Door needs to be trimmed at bottom by a skilled craftsman at the master
bedroom. A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(7) The closet door rubs floor when opened.
Door needs to be trimmed at bottom by a skilled craftsman at the master
bedroom. A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(8) The entry door missing weather-stripping
at the furnace room. A repair or replacement is needed. A qualified
person should repair or replace as needed.
| ||||||
|
(9) The French doors do not shut properly at
the basement. A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(10) The entry door rubs floor when opened.
Door needs to be trimmed at bottom by a skilled craftsman at the basement.
A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
|
(11) The closet door rubs floor when opened
and hinge pin is missing. Door needs to be trimmed at bottom by a skilled
craftsman at the hallway basement. A repair or replacement is needed.
A qualified person should repair or replace as needed.
| ||||||
|
(12) The entry door rubs floor when opened.
Door needs to be trimmed at bottom by a skilled craftsman at the basement.
A repair or replacement is needed. A qualified person
should repair or replace as needed.
| ||||||
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) | |||||
| Inspected, Repair or Replace | ||||||
|
One window does not lock properly at the
Master Bedroom. This is a small repair. A qualified person
should repair or replace as needed.
| ||||||
| 5.5 | ROOF STRUCTURE AND ATTIC | ||||
| Inspected, Repair or Replace | |||||
|
There is mold growing on roof truss.
Areas have been cleaned, however, it was not cleaned properly. Mold
is visible on truss and some has been covered up with insulation and
drywall.
| |||||
| 6.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS | |||
| Inspected, Repair or Replace | ||||
|
(1) Washing machine pan does not fit drain in
floor at laundry room. Repairs are needed using a qualified person.
| ||||
|
(2) The plumbing waste line is not secured to
wall at the laundry room. Repairs are needed. A qualified licensed
plumber should repair or correct as needed.
| ||||
| 6.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |||
| Inspected, Repair or Replace | ||||
|
(1) The countertop needs silicone caulking
around edges at the laundry room. Repairs are needed to prevent possible
leak or seepage through crack or damaged area A qualified person should
repair as necessary.
| ||||
|
(2) The sink needs caulking at wall at the
half bath. Repairs are needed A qualified licensed plumber should
repair or correct as needed.
| ||||
|
(3) The control knob, tub faucets is missing
decorative screw cover at the hall bath. Repairs are needed.
A qualified licensed plumber should repair or correct as needed.
| ||||
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | ||
| Inspected, Repair or Replace | |||
|
(1) One "three-prong" outlet is loose in wall
and cover-plate does not fit properly in the living room. This is a safety
issue that needs to be corrected. A qualified licensed electrician
should perform repairs that involve wiring.
| |||
|
(2) At least one "three-prong" outlet is loose
in wall at bar in basement. This is a safety issue that needs to be
corrected. A qualified licensed electrician should perform repairs
that involve wiring.
| |||
|
(3) The light fixture is incorrect
type at the main entry door basement. Electrical issues are
considered a hazard until repaired. A qualified licensed electrician
should perform repairs that involve wiring.
| |||
|
(4) Two "three-prong" 20 amp outlets show
false ground in the garage when tested. This is a safety issue that needs
to be corrected. A qualified licensed electrician should perform
repairs that involve wiring.
| |||
| 9.0 | INSULATION IN ATTIC | ||
| Inspected, Repair or Replace | |||
|
Insulation is blown cellulose it should be R
30 for ceiling (attic) the measuring chart does not show R 30.
| |||
Prepared Using HomeGauge http://www.homegauge.com/ SHGI (c)
2000-2004 : Licensed To Assured Home Inspections Inc.
|
INVOICE |
| Assured Home Inspections Inc. 4109 Waterford Dr. Charlotte, NC 28226 Cell Phone 704-576-5993 Office 704-542-0468 Inspected By: Ben Jimison NC 1654, SC 1103 |
Inspection Date: 2/7/2007 Report ID: |
| Customer Info: | Inspection Property: |
| Mr. Tommy Merritt Mrs. Peggy Meritt 8868 Collins Road Fort Mill SC 29715 Customer's Real Estate Professional: Andy Man Pulte |
10474 Bethpage Dr. Fort Mill, SC 29715 |
Inspection Fee:
| ||||||||
|
Tax $0.00 | ||||||||
| Total Price $400.00 |
Payment Method:
Payment
Status:
Note: